Dear visitors! Thank you for visiting the updated PILOT website. We are currently filling the portal with information. We apologize for the temporary inconvenience.
Products
Fleet management and telematics
Telematics
Geofences
Fuel Cards
Toll Roads
Waste Management
EcoDriving
Crash Detection
Video Solutions
MDVR
ADAS
DMS
CCTV
AI Dashcams
Traffic cameras with AI
Body worn cameras
Logistics
PTM
TMS
Shaing
Autoconductor
Security
GARM
People
Indoor navigation
Industrial
Utilities
Development
Solutions
Fleet Management
Costs reducing
Fleet monitoring
Fuel Management
Fuel cards solution
Gas station automation
Video
MDVR
ADAS
DMS
CCTV
Face ID solutions
Traffic management solutions
Security
GARM
PILOT Lite
Industry Specific Solutions
Agriculture
Development
Logistics and transport
Delivery and courier service
Passenger Traffic
Passenger traffic management
Vehicles rent & leasing solutions
Blog & Resources
Blog
Articles
News
Relieses
Useful Materials
Users
User’s Guide
Privacy policy
PILOT User Agreement
PILOT Cookie Policy
Frequently Asked Questions concerning GDPR
Partners&Clients
Partners’
PILOT partnership programs
For equipment manufactures
Clients’
Customer reviews
Support Request
Equipment
Company
PILOT Platform
Who we are
Aim and philosophy
Data privacy and security
Contact us
Client registration form
Support Request
Language
Language
English
Español
Português
EN
ES
PT
Demo
Home
/
Equipment
/
Galileo
Parameters
Name
Description
HardVersion
Hardware version
SoftVersion
Firmware version
IMEI
IMEI in ASCII
ID
Identifier of a device
NumberOfPacket
Number of an archive record
Height
Height, m
HDOP
One of the values:
HDOP, if GLONASS/GPS
module is coordinates source
Error in meters, if cellular base
stations are a source
StatusOfDevice
Status of device
Vsource
Supply voltage, mV
Vbattery
Battery voltage, mV
Temperature
Inside temperature, °C
OUT1, OUT2… OUTN
Status of outputs
DIN1, DIN2 … DINN
Status of imputs
AccX
acceleration by X axis
AccY
acceleration by Y axis
AccZ
acceleration by Z axis
IN0
Input voltage 0
Depending on settings:
1. voltage, mV,
2. number of pulses;
3. frequency,Hz.
IN1
Input voltage 1
Depending on settings:
1. voltage, mV,
2. number of pulses;
3. frequency,Hz.
IN2
Input voltage 2
Depending on settings:
1. voltage, mV,
2. number of pulses;
3. frequency,Hz.
IN3
Input voltage 3
Depending on settings:
1. voltage, mV,
2. number of pulses;
3. frequency,Hz.
Omnicomm000
RS232 0
Omnicomm001
RS232 1
Temperature0/1/2../7
Thermometer 1/2/../7 identifier and
measured temperature, °C
iButton
First iButton key identification
number
FMS_TF
CAN-bus and CAN-LOG data
(CAN_A0). Fuel used by
a vehicle from the date of
manufacturing, l
FMS_AF
CAN-bus and CAN-LOG data
(CAN_A1). Fuel level, %;
coolant temperature, ⁰C;
Enginespeed, rpm.
FMS_L
CAN-bus and CAN-LOG data
(CAN_B0).
Vehicle`s mileage, m.
FMS
CAN_B1
CAN8_0
CAN8BITR0
or vehicle speed from
CAN-LOG, km/h
CAN8_1
CAN8BITR1 or the 2rd byte
of prefix S CAN-LOG
iButton_ID
The second iButton key
identification number
Mileage
Total mileage according to
GPS/GLONASS units data, m
iButton_State
State of iButton keys, identifiers
of which are set by iButton
command
AIN0
Input 4 values.
Depending on settings:
1. voltage, mV
2. number of pulses
3. frequency, Hz
AIN1
Input 5 values.
Depending on settings:
1. voltage, mV
2. number of pulses
3. frequency, Hz
AIN2
Input 6 values.
Depending on settings:
1. voltage, mV
2. number of pulses
3. frequency, Hz
AIN3
Input 7 values.
Depending on settings:
1. voltage, mV
2. number of pulses
3. frequency, H
DS1923_0 /1/2…/7
Zero DS1923 sensor
Identifier, measured
temperature ºC and
humidity %
RS485_0 1/2
RS485 [N]. Fuel level
sensor with address N
llst0
Extended data RS232[0].
Depending on settings:
1. Temperature from fuel
level sensors connected
to RS232 0, °C
2. Weight, received from
weight identifier
rs232_1
Expanded data RS232[1].
Depending on the settings:
1. Temperature from fuel
level sensors connected
to Rs232[1], °C
2. Weight received from
weight identifier
llst1
Temperature from fuel
level sensors connected
to RS485 port with
address 0, °C
llst2
Temperature from fuel
level sensors connected
to RS485 port with
address 1, °C
llst3
Temperature from fuel
level sensors connected
to RS485 port with
address 2, °C
Input8 /9/10/…/13
Input N value.
Depending on the settings, one of the options is the following:
1. voltage, mV;
2. number of pulses;
frequency, Hz.
Milliseconds
eco_acc
acceleration, units, 100 = 1g = 9,8 m/s2
eco_stop
breaking, units, 100 = 1g = 9,8 m/s2
eco_angl
cornering acceleration, 100 = 1g = 9,8 m/s2
eco_break
strike on bumps, 100 = 1g = 9,8 m/s2
TahoType
1 – SHTRIH-Taho RUS
2 – Atol Drive 5, Atol Drive Smart
TahoState
0 – not connected (did not try to connect after starting the terminal)
1 – not authorized (tried to log in but failed)
2 – authorized
TahoMode
not supported
TahoSpeed
Vehicle speed
TahoTrip
Trip distance
TahoIgnition
Ignition status
TahoMass
TahoFeryTrain
TahoActivity
0 – rest
1 – ready
2 – work
3 – driving
TahoCardType
card type:
1 – Driver card
5 – “Non-driver” card
TahoCardNumber
Driver card number
TahoActivity1
TahoActivity1
TahoActivityTime
TahoDrivingTime
TahoRestlessTime
TahoTahoVin
VIN code in ASCII
TahoVrn
Vehicle plate number
On the page:
Parameters
Site search
Search
Type your request or just describe your question in the feedback fom: we will contact you and explain everything in details
Contact us